1) Testing building foundation piles by crosshole sonic logging.
2) inspecting concrete defects by ultrasonic method, such as uncompacted ,cellular, hole area.
3) Detecting strength of concrete by ultrasonic-rebound combine method.
4) Detecting depth of concrete crevice by ultrasonic method.
5) Detecting defects of one hole by one trigger two receive.
6) Testing dynam performance of geotechnical investigation, rock, concrete etc.
Features
1) Fast and precise Automatic judge the sound parameters. Real-time wave display to assure test efficiency.
2) Humanized software design. software is designed apply to user and construction plant application directly,. the HELP section ensures user friendly-user handling.
3) Displaying the test data graphically. User can view analyzing result directly.
4) Linking the rebound apparatus directly. Detecting strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly, and get strength of concrete in time. The function has been applied for national patent.
5) Being sensitive to receiving signal. Can receive signal more than 10m in concrete without defects.
6) Can supply smooth power for radial energy transducer needless external power.
7) Standard USB storage with big capacity.
8) Interior lithium battery supply power for apparatus work more than 6 hours. More than 12 hours combined with external lithium battery, this can match requirement of long time field testing.
9) Portable, small, light apparatus (1.75Kg).
10) Extending function for testing thickness of concrete by impacting echo method.
11) Professional and powerful analysis software on windows system. It can export the data to Excel or word for advanced analysis.
Technical Data
Item |
specifications |
Item |
specifications |
Main Control Unit |
high-performance Embed Computer |
Display |
640×480High brightness TFT Panel |
Input |
Keyboard |
storage |
1G(Interior)+2G(U-Disk) |
interface |
USB |
|
|
Receive Channel |
One |
Max Sample Data length |
64k |
Trigger Mode |
Continuous Trigger, External Trigger |
Trigger Voltage(V) |
65,125,250,500,1000 selectable |
Receive sensitivity |
≤30μv |
Amplifier gain |
82dB |
Amplifier bandwidth |
10KHz to 300 kHz |
Sample Periods |
0.05μs to 6.4μs,8 grade selectable |
Sound time accuracy |
0.05μs |
amplifier resolution |
0.39% |
Power |
Interior lithium battery,work more than 6 hours |
Size |
260 mm×185 mm×60 mm |
External lithium battery, work more than 6 hours(select) |
weight |
1.75 kg(include lithium battery) |
|
DC 12V |
temperature |
-10℃—+40℃ |
|
AC 100V -240V,50/60Hz |
|
|